Softstart Resistor - Type Tg Series; Softstart Resistor; Softstart Resistor Mcb - Emerson SP1201 Installation Manual

Unidrive sp regen series 200v 400v 575v 690v
Table of Contents

Advertisement

Safety
Product
Introduction
Information
information
Table 10-23 575V / 690V Regen inductor specifications
Inductor part
Amps
number
4401-0210
19
4401-0211
22
4401-0212
27
4401-0213
36
4401-0214
43
4401-0215
52
4401-0216
63
4401-0217
85
4401-0218
100
4401-0219
125
4401-0220
144
4401-0221
168
4401-0222
192
10.4.2

Softstart resistor - type TG series

The start-up circuit limits the amount of current flowing into the DC bus of
the Regen drive and motoring drive(s) when the supply is first switched
on.
The softstart resistors required for single regen multiple motoring
applications are as specified in the following table. Resistor energy pulse
rating and overload are non-standard and therefore important.
The following resistors can be configured to meet the required
resistance (series parallel arrangements).
Table 10-24 Softstart resistor
CT part no
Resistance
1270-3157
150
1270-2483
48

Softstart resistor MCB

Protection for the softstart circuit is provided using a thermal overload to
protect against a high impedance short circuit, and a separate magnetic
overload to protect against a direct short circuit.
Table 10-25 Softstart resistor MCB
CT part
Rated
number
current
4133-0117
0.3
4133-0217
1
4133-0277
2
10.4.3
Switching frequency filter
The AC input terminals of a Regen drive produce a PWM output voltage,
which has a sinusoidal component at line frequency, plus significant
harmonics at the switching frequency and its multiples.
Switching frequency filter inductors
The following inductors are standard 3-phase inductors, rated at drive
rated current for a single regen system. They carry only 50/60Hz current
with a negligible amount of high frequency current.
NOTE
The switching frequency filter inductors need to be rated to the total
current requirement of the system.
Unidrive SP Regen Installation Guide
Issue Number: 2
System
Mechanical
design
installation
Losses
L
mH
W
mm
mm
5.3
268
325
220
4.6
288
325
220
3.8
322
325
220
2.8
348
370
260
2.4
398
375
280
1.9
456
395
280
1.6
503
395
280
1.20
605
430
300
1.00
950
500
350
0.80
880
490
320
0.70
1022
500
320
0.60
1656
555
300
0.53
1350
600
350
Rated
No of
Voltage
poles
480
1
480
1
480
1
www.controltechniques.com
Electrical
Getting
Optimisation
installation
started
D
H
Weight
Fixing centres (x * y)
mm
kg
320
32
320
33
320
39
360
55
360
65
360
77
360
97
410
110
480
170
480
130
480
140
480
165
480
180
Technical
Component
Parameters
data
sizing
Fixing
mm
mm
200 x 180
11
200 x 180
11
200 x 180
11
240 x 220
11
240 x 240
11
240 x 240
11
240 x 240
11
280 x 260
11
320 x 260
11
320 x 260
11
320 x 260
11
320 x 240
11
320 x 260
11
Diagnostics
Fixing
type
A
197