No. Of Auto-Reset Attempts; Auto-Reset Delay; Hold Drive Healthy Until Last Attempt; Action On Trip Detection - Emerson SP1201 Installation Manual

Unidrive sp regen series 200v 400v 575v 690v
Table of Contents

Advertisement

Safety
Product
Introduction
Information
information
10.34

No. of auto-reset attempts

Drive mode
Regen
Bit
SP
Coding
Range
Regen
Default
Regen
Update rate
Background
10.35

Auto-reset delay

Drive mode
Regen
Bit
SP
Coding
Range
Regen
Default
Regen
Update rate
Background
If Pr 10.34 is set to zero then no auto reset attempts are made. Any other value will cause the drive to automatically reset following a trip for the
number of times programmed. Pr 10.35 defines the time between the trip and the auto reset (this time is always at least 10s for OI.AC, OI.br trips,
etc.). The reset count is only incremented when the trip is the same as the previous trip, otherwise it is reset to 0. When the reset count reaches the
programmed value, any further trip of the same value will not cause an auto-reset. If there has been no trip for 5 minutes then the reset count is
cleared. Auto reset will not occur on a UU, Et, EEF or HFxx trips. When a manual reset occurs the auto reset counter is reset to zero.
10.36

Hold drive healthy until last attempt

Drive mode
Regen
Bit
SP
Coding
1
Default
Regen
Update rate
Background
If this parameter is 0 then Pr 10.01 (Drive healthy) is cleared every time the drive trips regardless of any auto-reset that may occur. When this
parameter is set the 'Drive healthy' indication is not cleared on a trip if an auto-reset is going to occur.
10.37

Action on trip detection

Drive mode
Regen
Bit
SP
Coding
Range
Regen
Default
Regen
Update rate
Background
Braking IGBT trip mode
0
Trip
1
Trip
2
Disable
3
Disable
If stop on low priority trips is selected the drive will stop before tripping except in regen mode where the drive trips immediately. Low priority trips are:
th, ths, Old1, cL2, cL3, SCL.
Unidrive SP Regen Installation Guide
Issue Number: 2
System
Mechanical
design
installation
FI
DE
Txt VM DP
ND
0 to 5
0
FI
DE
Txt VM DP
ND
1
0.0 to 25.0 s
1.0
FI
DE
Txt VM DP
ND
0
FI
DE
Txt VM DP
ND
0 to 3
0
Stop on low priority trips
www.controltechniques.com
Electrical
Getting
Optimisation
installation
started
RA NC NV
PT
US RW BU
1
RA NC NV
PT
US RW BU
1
RA NC NV
PT
US RW BU
1
RA NC NV
PT
US RW BU
1
No
Yes
No
Yes
Technical
Component
Parameters
data
PS
1
1
PS
1
1
PS
1
PS
1
1
Diagnostics
sizing
151

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents