Maximum Permissible Continuous Output Current - Emerson SP1201 Installation Manual

Unidrive sp regen series 200v 400v 575v 690v
Table of Contents

Advertisement

Safety
Product
Introduction
Information
information
Table 10-3

Maximum permissible continuous output current

Nominal
Model
rating
kW
hp
SP1201
1.1
1.5
SP1202
1.5
2.0
SP1203
2.2
3.0
SP1204
3.0
3.0
SP2201
4.0
5.0
SP2202
5.5
7.5
SP2203
7.5
10
SP3201
11
15
SP3202
15
20
SP4201
18.5
25
SP4202
22
30
SP4203
30
40
SP5201
37
50
SP5202
45
60
SP1401
1.1
1.5
SP1402
1.5
2.0
SP1403
2.2
3.0
SP1404
3.0
5.0
SP1405
4.0
5.0
SP1406
5.5
7.5
SP2401
7.5
10
SP2402
11
15
SP2403
15
20
SP2404*
15
20
SP3401
18.5
25
SP3402
22
30
SP3403
30
40
SP4401
37
50
SP4402
45
60
SP4403
55
75
SP5401
75
100
SP5402
90
125
SP6401
110
150
SP6402
132
200
SP3501
3.0
3.0
SP3502
4.0
5.0
SP3503
5.5
7.5
SP3504
7.5
10
SP3505
11
15
SP3506
15
20
SP3507
18.5
25
SP4601
18.5
25
SP4602
22
30
SP4603
30
40
SP4604
37
50
SP4605
45
60
SP4606
55
75
SP5601
75
100
SP5602
90
125
SP6601
110
150
SP6602
132
175
Unidrive SP Regen Installation Guide
Issue Number: 2
System
Mechanical
design
installation
Normal Duty
Maximum permissible continuous output current
(A) for the following switching frequencies
3kHz
4kHz
6kHz
8kHz
5.2
6.8
9.6
11.0
10.9
15.5
19.7
18.9
17.3
15.9
19.5
18.6
17.2
15.8
42.0
54.0
52.8
47.0
68.0
80.0
87.4
130
154
2.8
3.8
5.0
6.9
8.8
7.3
6.0
10.1
9.0
7.3
6.0
15.3
14.2
11.8
10.0
15.7
14.2
11.8
10.0
16.8
15.0
12.2
10.1
22.3
19.8
15.8
12.8
35.0
33.5
28.5
43.0
41.5
34.2
28.7
46.0
41.5
34.2
28.7
68.0
66.8
54.9
83.0
81.6
66.5
52.3
86.5
86.2
71.3
59.3
138
105.9
87.4
141
140
112
92
191.5
190.1
147.6
198.4
180.6
138.1
5.4
6.1
8.4
11.0
16.0
14.7
22.0
17.8
14.7
24.6
22.0
17.8
14.7
22.0
27.0
24.7
36.0
30.7
24.7
43.0
39.6
30.7
24.7
45.6
39.5
30.7
24.7
51.9
44.9
34.7
27.7
83
69
51
40
83
69
51
40
98
81
59
98
81
59
www.controltechniques.com
Electrical
Getting
Optimisation
installation
started
@ 50°C (122°F) ambient for wall mounted drives
Nominal
rating
12kHz
16kHz
kW
hp
0.75
1.0
1.1
1.5
9.0
1.5
2.0
9.5
8.3
2.2
3.0
13.5
11.5
3.0
3.0
13.5
11.5
4.0
5.0
13.4
11.5
5.5
7.5
38.2
7.5
10
38.2
11
15
15
20
18.5
25
22
30
30
40
37
50
0.75
1.0
1.1
2.0
3.9
1.5
3.0
5.1
3.9
2.2
3.0
4.2
3.1
3.0
5.0
4.2
3.1
4.0
5.0
7.3
5.5
5.5
10
7.3
5.5
7.5
10
7.1
11
20
8.6
5.9
15
20
21.5
16.9
15
25
21.0
16.0
18.5
30
21.0
22
30
30
50
37
60
45
75
55
100
75
125
90
150
110
150
2.2
2.0
3.0
3.0
4.0
5.0
5.5
7.5
7.5
10
11
15
15
20
15
20
18.5
25
22
30
30
40
37
50
45
60
55
75
75
100
90
125
110
150
Technical
Component
Parameters
data
sizing
Heavy Duty
Maximum permissible continuous output current
(A) for the following switching frequencies
3kHz
4kHz
6kHz
8kHz
4.3
5.8
7.5
10.6
12.6
17.0
15.7
19.2
18.4
17.0
15.7
31.0
42.0
56.0
68.0
80.0
105
130
2.1
3.0
4.2
5.8
7.6
7.2
6.0
9.5
9.0
7.2
6.0
13.0
11.7
9.9
15.5
14.1
11.7
9.9
16.7
15.0
12.2
10.1
22.3
19.8
14.0
11.2
32.0
30.7
26.1
40.0
34.1
28.4
46.0
41.5
33.6
28.3
60.0
46.7
38.3
68.2
58.6
46.0
37.7
86.5
74.7
60.1
49.8
112.7
96.4
74.5
59.9
140
123
99.0
82.0
180
157.9
121.5
190
157.9
116.2
4.1
5.4
6.1
9.5
12.0
18.0
16.8
13.9
22.0
20.4
16.7
13.9
19.0
22.0
27.0
36.0
30.7
24.7
43.0
39.6
30.7
24.7
51.9
44.9
34.7
27.7
63
63
47
38
75
62
45
36
98
81
59
98
81
59
Diagnostics
12kHz
16kHz
9.5
8.3
11.4
13.4
11.4
13.3
11.4
37.2
3.8
4.8
3.7
4.2
3.1
4.2
3.1
7.3
5.5
7.3
5.5
7.1
5.1
7.3
4.6
19.7
15.4
20.7
16.0
20.8
185

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents