6.21

Powered-up time: hours.minutes

Drive mode
Regen
Bit
SP
Coding
Range
Regen
Update rate
Background
The powered-up clock always starts at zero each time the drive is powered-up. The time can be changed by the user from the keypad, serial comms
or an application module. If the data is not written with the various parts in the correct range (i.e. minutes are greater than 59, etc.) the clock is set to
zero on the next minute. This clock may be used for time stamping the trip log if Pr 6.28 = 0.
6.22

Run time: years.days

Drive mode
Regen
Bit
SP
Coding
Range
Regen
Update rate
Background
6.23

Run time: hours.minutes

Drive mode
Regen
Bit
SP
Coding
Range
Regen
Update rate
Background
The run time clock increments when the drive inverter is active to indicate the number of minutes that the drive has been running since leaving the
Control Techniques factory. This clock may be used for time stamping the trip log if Pr 6.28 = 1.
6.24

Energy meter: MWh

Drive mode
Regen
Bit
SP
Coding
Range
Regen
Update rate
Background
6.25
Energy meter: kWh
Drive mode
Regen
Bit
SP
Coding
Range
Regen
Update rate
Background
Pr 6.24 and Pr 6.25 form the energy meter that indicates energy supplied to/from the drive in kWh. For motor control modes a positive value indicates
net transfer of energy from the drive to the motor. For regen mode a positive value indicates a net transfer of energy from the supply to the drive. The
energy meter is reset and held at zero when Pr 6.17 is one.
6.26
Running cost
Drive mode
Regen
Bit
SP
Coding
Range
Regen
Update rate
Background
Instantaneous read out of the cost/hour of running the drive. This requires Pr 6.16 to be set up correctly.
114
System
Mechanical
design
installation
FI
DE
Txt VM DP
ND
2
1
0 to 23.59 Hours.Minutes
FI
DE
Txt VM DP
ND
3
1
0 to 9.364 Years.Days
FI
DE
Txt VM DP
ND
2
1
0 to 23.59 Hours.Minutes
FI
DE
Txt VM DP
ND
1
1
±999.9 MWh
FI
DE
Txt VM DP
ND
2
1
±99.99 kWh
FI
DE
Txt VM DP
ND
1
1
±32,000
www.controltechniques.com
Electrical
Getting
Optimisation
installation
started
RA
NC
NV
PT
US RW BU
1
1
RA
NC
NV
PT
US RW BU
1
1
RA
NC
NV
PT
US RW BU
1
1
RA
NC
NV
PT
US RW BU
1
1
RA
NC
NV
PT
US RW BU
1
1
RA
NC
NV
PT
US RW BU
1
1
Technical
Component
Parameters
data
PS
1
1
PS
1
1
PS
1
1
PS
1
PS
1
PS
Unidrive SP Regen Installation Guide
Diagnostics
sizing
Issue Number: 2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents