Indicates the drive is not in the trip state. If Pr 10.36 is one and auto-reset is being used, this bit is not cleared until all auto-resets have been
attempted and the next trip occurs. The control board LED reflects the state of this parameter: LED on continuously = 1, LED flashing = 0.
10.02
Drive active
Drive mode
Regen
Bit
SP
Coding
1
Update rate
4ms
Indicates that the drive inverter is active.
10.09
Drive output is at current limit
Drive mode
Regen
Bit
SP
Coding
1
Update rate
4ms
Indicates that the current limits are active.
10.10
Regenerating
Drive mode
Regen
Bit
SP
Coding
1
Update rate
4ms
Indicates that power is being transferred from the drive to the supply.
10.11
Braking IGBT active
Drive mode
Regen
Bit
SP
Coding
1
Update rate
4ms
Indicates that the Braking IGBT is active. If the IGBT becomes active this parameter is held on for at least 0.5s so that it can be seen on the display.
10.12
Braking resistor alarm
Drive mode
Regen
Bit
SP
Coding
1
Update rate
Background
This parameter is set when the braking IGBT is active and the braking energy accumulator is greater than 75%. This parameter is held on for at least