SMA Solar Technology AG
No.
Name
320.05
BatEgyCntOut
320.06
AhCntIn
320.07
AhCntOut
320.08
BatTmpPkMin
320.09
BatTmpPkMax
320.10
EquChrgCnt
320.11
FulChrgCnt
320.12
BatCurOfsErr
320.13
OcvPointCnt
320.15
AhCntFul
320.16
AhCntEqu
320.17
BatVtgPk
320.18
BatCurPkIn
320.19
BatCurPkOut
320.20
SocHgm100
320.21
SocHgm090
320.22
SocHgm080
320.23
SocHgm070
320.24
SocHgm060
320.25
SocHgm050
320.26
SocHgm040
320.27
SocHgm030
320.28
SocHgm020
320.29
SocHgm010
Operating Manual
Description
Energy meter for battery discharging in kWh
Battery charging counter in Ah
Battery discharging counter in Ah
Minimum battery temperature [°C]
Maximum battery temperature °C
Number of equalization charges of the battery
Number of full charges of the battery
Estimated offset error of battery current in A (expert mode)
Open-circuit voltage points meter (expert mode)
Relative battery discharging since the last full charge in 
Ampere-hour meter for battery discharging since the last equalization charge
Ah
in 
100 Ah
Maximum battery voltage reached since the last start in V
Maximum battery current reached since the last start in charge direction in A
Maximum battery current reached since the last start in discharge direction
in A
Percentage frequency distribution of state of charge (SOC) when SOC is in
the range of 100% to and including 90%, based on time in % (expert mode)
Percentage frequency distribution of state of charge (SOC) when SOC is in
the range of 90% to and including 80%, based on time in % (expert mode)
Percentage frequency distribution of state of charge (SOC) when SOC is in
the range of 80% to and including 70%, based on time in % (expert mode)
Percentage frequency distribution of state of charge (SOC) when SOC is in
the range of 70% to and including 60%, based on time in % (expert mode)
Percentage frequency distribution of state of charge (SOC) when SOC is in
the range of 60% to and including 50%, based on time in % (expert mode)
Percentage frequency distribution of state of charge (SOC) when SOC is in
the range of 50% to and including 40%, based on time in % (expert mode)
Percentage frequency distribution of state of charge (SOC) when SOC is in
the range of 40% to and including 30%, based on time in % (expert mode)
Percentage frequency distribution of state of charge (SOC) when SOC is in
the range of 30% to and including 20%, based on time in % (expert mode)
Percentage frequency distribution of state of charge (SOC) when SOC is in
the range of 20% to and including 10%, based on time in % (expert mode)
Percentage frequency distribution of state of charge (SOC) when SOC is in
the range of 10% to and including 0%, based on time in % (expert mode)
13 Parameters in Sunny Remote Control
Ah
100 Ah
SI30M-44M-60H-80H-BE-en-33
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓