SMA SUNNY ISLAND 3.0M Operating Manual page 110

Sunny remote control
Hide thumbs Also See for SUNNY ISLAND 3.0M:
Table of Contents

Advertisement

13 Parameters in Sunny Remote Control
113# Slave1
No.
Name
113.01
InvOpSttSlv1
113.02
InvPwrAtSlv1
113.03
InvVtgSlv1
113.04
InvCurSlv1
113.05
InvPwrRtSlv1
113.06
Rly1SttSlv1
113.07
Rly2SttSlv1
113.09
TrfTmpSlv1
113.10
HsTmpSlv1
110
SI30M-44M-60H-80H-BE-en-33
Description
Operating state of slave 1
Active power of slave 1 at line
conductor L2 in kW
Line voltage of slave 1 at line
conductor L2 in V
Line current of the slave 1 at line
conductor L2 in A
Reactive power of slave 1 at line
conductor L2 in kVAr (expert
mode)
Multifunction relay status 1 of
slave 1
Multifunction relay status 2 of
slave 1
Temperature of the transformer in
slave 1 in °C (expert mode)
Temperature of the heat sink in
slave 1 in °C (expert mode)
SMA Solar Technology AG
Value
Explanation
(Plain text
no.)
Init (1)
Initialization
Startup (2)
Switch from standby to
operation
Standby (3)
Standby
Run (4)
Operation
I-Loop (5)
Current-controlled gener-
ator operation
Error (6)
Error status
Off
Multifunction relay is de-
activated.
On
Multifunction relay is acti-
vated.
Off
Multifunction relay is de-
activated.
On
Multifunction relay is acti-
vated.
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Operating Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sunny island 6.0hSunny island 4.4mSunny island 8.0h

Table of Contents