13 Parameters in Sunny Remote Control
No.
Name
250.09
ComAdr
250.11
AfraEna
250.23
Box
250.24
ClstMod
250.28
ChrgCtlOp
250.30
RnMod
146
SI30M-44M-60H-80H-BE-en-33
Description
Value
Communication ad-
0 to 65535
dress (non-ad-
justable)
Automatic frequency
Disable
synchronization
Enable
(AFRA) (expert
mode)
Type of AC subdis-
None
tribution: / Multiclus-
MC-Box-6-1x
ter-Box
MC-Box-9-1x
MC-
Box-12-1x
MC-
Box-12-2x
MC-
Box-36-1x
Cluster type (ad-
SingleClst
justable in QCG)
MainClst
ExtnClst
Type: other DC
Auto
sources (expert
mode)
NoFrq
SMA
Run Mode
RunAlways
Behavior of the clus-
ter in the event of a
device fault
StopAlways
SMA Solar Technology AG
Explanation
Disable
Enable
None
Multicluster-Box 6.3
Multicluster-Box 9.3
Multicluster-Box 12.3
Multicluster-Box 12.3 of the
type MC-BOX-12.3-20
Multicluster-Box 36.3
Single cluster
Main cluster
Extension cluster
AC sources and DC charge
controllers
Other DC charge controllers
The DC charge controllers
are not Sunny Is-
land Charger devices and
there are no AC sources in
the system.
Communicative coupled DC
charge controllers, e.g. Sun-
ny Island Charger
No AC sources in the sys-
tem.
In the event of a slave de-
vice error, the cluster re-
mains in operation
In the event of a device er-
ror, the cluster stops opera-
tion
Default
Value
✓ ✓
1
✖ ✓
✖ ✓
✓ ✓
✖ ✓
Auto
✓ ✓
RunAlwa
ys