1. SL-VGU1-EC Station Address (Rotary Switch)
Rotary switch: 1st controller "1", 2nd controller "256"
2. SL-VGU1-EC Settings (CONFIG Mode)
Setting of transmission
mode
Setting of display to decimal /
hexadecimal number display
Setting of number of
I/O control points
I/O setting 0
I/O setting 1
I/O setting 2
I/O setting 3
3. Wiring
Connect two SL-VGU1-EC controllers from the EtherCAT master.
4. Wiring (S-LINK V System Side)
Connect the S-LINK V I/O units to the corresponding SL-VGU1-EC.

Setting of S-LINK V system side

1. Set the mode selection switch to CONFIG, and then turn on the power.
2. Various setting items will be displayed. Set these items considering the system conditions.
For a detailed description of setting, refer to page 36 'CONFIG Mode.'

System setting

After turning on the power of the S-LINK V system for the first time, be sure to carry out system setting.
After system setting, the system can recognize the addresses of the connected S-LINK V units, and the rec-
ognized addresses will be stored in the EEPROM. After this, errors 3, 4 and 5 will be detected using the recog-
nized address data stored in the EEPROM.
Since the address data of the connected units is stored in the EEPROM, it is not necessary to carry out system
setting each time after turning on the power. For a detailed description of system setting method, refer to page
36 'CONFIG Mode.'
CAUTION
If error 3 or 4 appears on the address display, the system has one of the following problems. Solve
the problem, and then be sure to carry out system setting. If system setting is carried out without
solving the problem, system setting may not be carried out properly.
● The line is disconnected between the I/O units of the system.
● An I/O unit is added after system setting.
SL-VGU1-EC
SL-VGU1-EC
(1st controller)
(2nd controller)
SL-VGU1-EC
(1st controller)
Setting of error 1
output operation
Setting of error 2
output operation
Setting of error 3
output operation
Setting of error 4
output operation
Setting of error 5
output operation
Output hold / clear
Starting
SL-VGU1-EC
(2nd controller)