Points; Chapter 9 Starting; Check Before Starting System; Power-On (Main Power And Local Power) - Panasonic SL-VGU1-EC User Manual

Ethercat s-link v gateway controller
Hide thumbs Also See for SL-VGU1-EC:
Table of Contents

Advertisement

Check before Starting System

Be sure to check the following items before starting the S-LINK V system or before turning on the power:
● Wiring conditions of the controller
● Shorted cables

SL-VGU1-EC wiring condition check

Visually check the terminals of the SL-VGU1-EC and the connected cable (terminals to which the cable is con-
nected).
S-LINK V terminal block connector side
No.
Designation
8
ERR
7
G
6
D
Main
line
5
0V
4
24V
3
0V
Input
2
24V
1
FG

Power-on (Main Power and Local Power)

CAUTION
● To use both the main power and the local power, be sure to turn on the local power first or turn on
both powers at the same time.
● To turn on the power for the first time after system installation, set the mode selection switch to
'CONFIG,' and then turn on the power.
At the completion of check before starting the system, turn on the power.
The S-LINK V system will be activated.

CONFIG Mode

In the CONFIG mode, the displayed items depend on the CONFIG mode selection timing.
● If the system is switched to the CONFIG mode before power-on:
Each item can be set.
● If the system is switched to the CONFIG mode after power-on:
Difference from the above-described case (CONFIG mode selection before power-on) is the following three

points:

• The default items will not be displayed.
• The preset items will not be displayed.
• The set value of each item is displayed, but changing the set value will not be possible.
For a detailed description of various settings for CONFIG mode and the set modes, refer to page 37 and fol-
lowing pages.
Wire color / Description
Error output
Black
White
Blue
Brown
External power supply input
Frame ground

Chapter 9 Starting

36

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents