Suzuki Madura GV700GL Service Manual page 298

Table of Contents

Advertisement

SERVICING INFORMATION 10-28
OIL PUMP
+
FUEL PUMP
+
WATER PUMP
Unit: mm (in)
ITEM
STANDARD
LIMIT
Oil pump reduction ratio
2.005
(
74/39
X
37/35
)
- -
Oil pressure (at 60°C, 140°F)
Above 4. 5 kg/cm
2 (
64 psi
)
Below 7. 5 kg/cm
2 (
107 psi
)
- -
at 3 000 r/min.
Fuel pump discharge
Over 500 ml/min.
- -
Fuel pump resistance
1-2 Q
- -
Water pump drive chain slack
3-5
- -
(
0.1-0.2
)
Water pump drive chain
64.7
- -
1 0-pitch length
(
2.55
)
CLUTCH
Unit: mm (in)
ITEM
STANDARD
LIMIT
Drive plate thickness
2.45-2.75
2.15
(
0.096-0.108
)
(
0.085
)
Drive plate claw width
15.8-16.0
15.0
(
0.62-0.63
)
(
0.59
)
Driven plate distortion
- -
0.1
(
0.004
)
Clutch spring free length
- -
34.0
(
1.34
)
Clutch master cylinder bore
14.000-14.043
- -
(
0.5512-0.5529
)
Clutch master cylinder piston diam.
13.957-13.984
- -
(
0.5495-0.5506
)
Clutch release cylinder bore
38.100-38.162
- -
(
1.5000-1.5024
)
Clutch release cylinder piston diam.
38.042-38.075
- -
(
1 .4977-1 .4990
)
THERMOSTAT
+
RADIATOR
+
FAN
ITEM
STANDARD
LIMIT
Thermostat valve opening
75.0 ± 1.5°C ( 167±2.7°F
)
- -
temperature
Thermostat valve lift
Over 8 mm ( 0.3 in) at 90°C ( 194°F)
- -
Radiator cap valve release pressure
0.90 ± 0.1 5 kg/cm
2 •
(
12.8 ± 2.1 psi, 90 ± 15 kPa
)
Electric fan thermo-switch
ON
105±3°C( 221 ± 5.4°F
)
- -
operating temperature
OFF
Approx. 98°C ( 208.4°F)
- -
Electric fan relay resistance
Approx. 70Q
- -
Thermo-gauge resistance
27.4Q at 100°C ( 212°F
l
- -
TRANSMISSION
Unit: mm (in)
ITEM
STANDARD
LIMIT
Primary reduction ratio
1.897
(
74/39
)
- -
Secondary reduction ratio
1.066
(
16/15
)
- -
Final reduction ratio
3.090
(
34/11
)
- -

Hide quick links: