AC GENERATOR CONTINUITY CHECK
• Using the pocket tester, check the continuity
between the lead wires of the stator.
Also check that the stator core is insulated.
NOTE:
When making this test, it is not necessary to
remove the AC generator.
09900 - 25002
Pocket tester
REGULATOR/RECTIFIER
• Remove the seat and left frame cover.
• Using the pocket tester (X 1kn range), measure
the resistance between the lead wires in the
following table.
If the resistance checked is incorrect, replace the
regulator/rectifier.
09900 - 25002
Pocket tester
Unit: kn
' " "'
EB
Probe of tester to:
~
R
0
B/W
Y@
R
~
00
00
00
00
00
0
.....
...
Approx.
~
Approx.
Approx. Approx.
Approx.
Q)
0
.....
80
35
50
50
50
"'
Q)
.....
~
....
B/W
Approx.
Approx.
Approx.
Approx.
Approx .
0
Q)
8.5
5.2
3
3
3
.0
e
Y@
Approx.
00
00
~
00
00
c..
3
CD
Y@
Approx.
~
3
00
00
00
00
Approx.
3
00
00
00
00
~
CAUTION:
As transistors, capacitors, Zener diodes, etc.
are used inside this regulator/rectifier, the re-
sistance values will differ when an ohmmeter
other than the Suzuki pocket tester is used.