COOLING SYSTEM
Inspect: 1 000, 12 000, 24 000 km
(600, 7 500, 15 000 mi)
Change cooling solution Every 2 years
Replace hoses Every 4 years
• Remove the radiator cap
CD
and drain plug ®.
WARNING:
Do not open the radiator cap when the
engine is hot, as you may be injured by
escaping hot liquid or vapor.
WARNING:
Cooling solution may be harmful if swallowed
or if it comes in contact with skin or eyes.
If cooling solution gets into the eyes or in
contact with the skin, it should be flushed
thoroughly with plenty of water. If swallowed,
induce vomitting and call physician immedia-
tely.
• Flush the radiator with fresh water if necessary.
PERIODIC MAINTENANCE AND TUNE-UP PROCEDURES 2-8
• Tighten the drain plug ®securely and loosen
the air bleeder
@.
• Install the specified cooling solution upto the
radiator inlet hole and tighten the air bleeder
@.
NOTE:
For cooling solution information, refer to
"cooling solution" section, page 5-3.
• Fill the reservoir tank to the "H" level with
cooling solution.
• Close the radiator cap securely.
• After warming up and cooling down the engine,
check the cooling solution level of the reservoir
tank and install the cooling solution to the "H"
level if the level is below "H".
3 500 ml (3.70 US qt) including reservoir tank
450 ml (0.48 US qt) reservoir tank
• Add 2 pks of anti-leakage material (Bar's leaks)
in the cooling solution.
99000-24240
Bar's leak