Example: Counter Start Source = OFF
Countermode=OFF
Counter is
IDLE
CounterStartSource=OFF
The counter starts on the counterReset Cmd.
•
The counter continues unless a new counterReset Cmd is received, which then restarts the
•
counter at 00.
When Counter Reset Source= 'Event' or 'CounterEnd' the counter is reset to 00 but does
•
not restart counting, until the next CounterReset Cmd.
Example: Counter Start Source = CounterEnd (itself)
Countermode=OFF
Counter is
IDLE
CounterStartSource=
CounterEnd (itself)
Counter starts when Counter Mode is set to Active.
•
A Counter Reset CMD will reset the counter to 00 and it then continues counting.
•
counterResetSource must be set to CounterEnd. When the counterValue feature reaches the
•
counterDuration value an event is generated and the counter is reset to 00, then continues.
•
126
Operational Reference
CounterStartSource=OFF
Countermode=Active
CounterWait
Trigger
Counter is incrementing
0
CounterStartSource=CounterEnd (itself)
Countermode=Active
CounterWait
Trigger
Counter is incrementing
0
CounterEnd Event Generated
Counter is
Counter
Active
Completed
CounterEnd Event Generated
Counter is
Counter
Active
Completed
Counter
Overflow
CounterResetSource=OFF
Counter Reset CMD
CounterResetSource=Event
CounterResetSource=CounterEnd
Counter Reset CMD
CounterResetSource=CounterEnd
Nano Series GigE Vision Camera