Case 5: Changing 'timestampModulo' during Acquisitions

Conditions:
initial timestampControlReset resets Timestamp counter
timestampModuloStartTime at 20
timestampModulo = 10
timestampModuloActualStartTime = first event (F1)
timestampModulo changes to 20
Case 5 shows that the Modulo value can be changed dynamically. Using the simple example of
case 1, after the second acquisition (F2) the Modulo value is changed from 10 to 20. The third
acquisition now occurs at modulo 20 time following the previous acquisition.
00
10
Nano Series GigE Vision Camera
20
30
F1
40
50
F2
Modulo value changed
Operational Reference
60
F3