Example: Counter Start Source = OFF

Countermode=OFF
Counter is
IDLE
CounterStartSource=OFF
The counter starts on the counterReset Cmd.
The counter continues unless a new counterReset Cmd is received, which then restarts the
counter at 00.
When Counter Reset Source= 'Event' or 'CounterEnd' the counter is reset to 00 but does
not restart counting, until the next CounterReset Cmd.

Example: Counter Start Source = CounterEnd (itself)

Countermode=OFF
Counter is
IDLE
CounterStartSource=
CounterEnd (itself)
Counter starts when Counter Mode is set to Active.
A Counter Reset CMD will reset the counter to 00 and it then continues counting.
counterResetSource must be set to CounterEnd. When the counterValue feature reaches the
counterDuration value an event is generated and the counter is reset to 00, then continues.
Nano Series GigE Vision Camera
CounterStartSource=OFF
Countermode=Active
CounterWait
Trigger
Counter is incrementing
0
CounterStartSource=CounterEnd (itself)
Countermode=Active
CounterWait
Trigger
Counter is incrementing
0
CounterEnd Event Generated
Counter is
Counter
Active
Completed
CounterEnd Event Generated
Counter is
Counter
Active
Completed
Counter
Overflow
CounterResetSource=OFF
Counter Reset CMD
CounterResetSource=Event
CounterResetSource=CounterEnd
Counter Reset CMD
CounterResetSource=CounterEnd
Operational Reference • 99