Acquisition And Transfer Control Feature Descriptions - Teledyne G3-GM10-M0641 User Manual

Genie nano series; genie nano xl series gige vision camera m640 series; m640 nir series; m800 series; m800 nir series; m1240 series; m1280 series; m1280 nir series; m1450 series; m1930 series; m1930 nir series; m1940 series; m1920 series; m2050 series; m2
Table of Contents

Advertisement

Acquisition and Transfer Control Feature Descriptions

The following table describes these parameters along with their view attribute and minimum
camera firmware version required. Additionally the Device Version column will indicate which
parameter is a member of the DALSA Features Naming Convention (denoted by DFNC), versus the
GenICam Standard Features Naming Convention (SFNC tag is not shown).
The Device Version number represents the camera software functional group, not a firmware
revision number. As Genie Nano capabilities evolve the device version tag will increase, therefore
identifying the supported function package. New features for a major device version release will be
indicated by
green text
Display Name
Acquisition Status
Selector
Acquisition Active
Acquisition Trigger Wait
Acquisition Status
Acquisition Mode
Single Frame
Multi-Frame
Continuous
Acquisition Frame Count
Acquisition Arm Cmd
Acquisition Start Cmd
Acquisition Stop Cmd
Acquisition Abort Cmd
Transfer Control
Nano Series GigE Vision Camera
for easy identification.
Feature & Values
AcquisitionStatusSelector
AcquisitionActive
AcquisitionTriggerWait
AcquisitionStatus
AcquisitionMode
SingleFrame
MultiFrame
Continuous
AcquisitionFrameCount
AcquisitionArm
AcquisitionStart
AcquisitionStop
AcquisitionAbort
TransferControlMode
Description
Selects the internal acquisition signal to read using
AcquisitionStatus.
Device is currently doing an acquisition of one or
many frames.
Device is currently waiting for a trigger to start the
acquisition.
Reads the state of the internal acquisition signal
selected using the Acquisition Status Selector feature.
(i.e. False / True)
Set the acquisition mode of the device. It defines the
number of frames to capture during an acquisition
and the way the acquisition stops.
One frame is captured for each AcquisitionStart
Command. An AcquisitionStop occurs at the end of
the Active Frame.
A sequence of frames is captured for each
AcquisitionStart Command. The number of frames is
specified by AcquisitionFrameCount feature. An
AcquisitionStop occurs at the end of the Active
Frame(s)
Frames are captured continuously with
AcquisitionStart until stopped with the AcquisitionStop
command.
Number of frames to be acquired in MultiFrame
acquisition mode.
Arms the device before an AcquisitionStart command.
This optional command validates all the current
features for consistency and prepares the device for a
fast start of the acquisition. If not used explicitly, this
command is automatically executed at the first
AcquisitionStart but will not be repeated for
subsequent ones unless a data transfer related
feature is changed in the device.
Start image capture using the currently selected
acquisition mode. The number of frames captured is
specified by AcquisitionMode feature.
Stops the Acquisition of the device at the end of the
current frame unless the triggerFrameCount feature is
greater than 1. (WO)
Aborts the acquisition immediately. This will end the
capture without completing the current Frame or
aborts waiting on a trigger. If no acquisition is in
progress, the command is ignored.
Sets the method used to control the transfer.
Device Version
(Ver.
1.05)
Operational Reference
& View
1.00
Expert
1.00
Expert
1.00
Beginner
1.00
Beginner
1.00
Guru
1.00
Beginner
1.00
Beginner
1.00
Beginner
1.00
179

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

G3-gm10-m0640G3-gm10-m0801G3-gm12-m0800G3-gm12-m0801G3-gm12-m0640G3-gm12-m0641 ... Show all

Table of Contents