Events Associated With Triggered Multiple Frame Synchronous Exposures - Teledyne G3-GM10-M0641 User Manual

Genie nano series; genie nano xl series gige vision camera m640 series; m640 nir series; m800 series; m800 nir series; m1240 series; m1280 series; m1280 nir series; m1450 series; m1930 series; m1930 nir series; m1940 series; m1920 series; m2050 series; m2
Table of Contents

Advertisement

Events Associated with Triggered Multiple Frame Synchronous
Exposures
The following timing graphic shows the primary events and acquisition timing associated with a
synchronous exposure of two frames from a single trigger event.
Input Signal
Event
TriggerDelay
FrameTrigger Inactive
Frame Inactive
Nano Series GigE Vision Camera
Multiple FrameActive (exposureAlignment=Synchronous )
ValidFrameTrigger
Event
Invalid Frame Trigger Period
FrameTrigger Active
FrameStart
FrameStart
Event (1)
Event (2)
FrameActive (1)
Exposure
Exposure(1)
Delay
ExposureStart
Event (1)
ExposureEnd
Event (1)
FrameActive (2)
ReadOut (1)
Exposure
Exposure(2)
Delay
ReadOut (2)
FrameTrigger Inactive
Frame Inactive
Operational Reference
191

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

G3-gm10-m0640G3-gm10-m0801G3-gm12-m0800G3-gm12-m0801G3-gm12-m0640G3-gm12-m0641 ... Show all

Table of Contents