Basic Information; Upgrading Or Replacing The Cpu; Preliminary Steps - Fujitsu PRIMERGY RX1330 M3 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY RX1330 M3:
Table of Contents

Advertisement

Processor (CPU)
11.1

Basic information

Supported CPUs
®
– one Intel
Quad-Core Xeon E3-12xxv6 or one Dual Core i3-7xxx or one
Dual Core Pentium G4xxx CPU
– one CPU socket LGA 1151
I
For system relevant information, refer to your server's hardware
configurator available online at the following address:
http://ts.fujitsu.com/products/standard_servers/index.htm
For Japan:
http://jp.fujitsu.com/platform/server/primergy/system/
11.2

Upgrading or replacing the CPU

Field Replaceable Unit
(FRU)
Tools: Phillips PH2 / (+) No. 2 screw driver
V
CAUTION!
CPUs are modules which are extremely sensitive to electrostatic
discharges and therefore must always be handled with care. After a CPU
has been removed from its protective sleeve or from its socket, place it
with its smooth side down on a non-conducting, antistatic surface. Never
push a CPU over a surface.

11.2.1 Preliminary steps

"Locating the defective server" on page 50
Ê
"Suspending BitLocker functionality" on page 71
Ê
"Shutting down the server" on page 53
Ê
"Disconnecting the power cord" on page 54
Ê
232
Upgrade and Maintenance Manual
Hardware: 15 minutes
Software: 5 minutes
RX1330 M3

Advertisement

Table of Contents
loading

Table of Contents