7.2.8
Replacing the 4 x 2.5-inch HDD backplane
Field Replaceable Unit
(FRU)
Tools: tool-less
7.2.8.1
Preliminary steps
"Locating the defective server" on page 50
Ê
"Shutting down the server" on page 53
Ê
"Disconnecting the power cord" on page 54
Ê
"Getting access to the component" on page 55
Ê
Ê Release all HDD/SSD modules and pull them out a few centimeters, see
section
"Removing 2.5-inch HDD/SSD modules" on page 147
I
The HDD/SSD modules need not to be removed. But if you want to
remove them nevertheless, check if all HDD/SSD modules are
uniquely identified so that you can reinsert them into their original
bays.
7.2.8.2
Removing the defective 4 x 2.5-inch HDD backplane
I
For configurations with up to four 2.5-inch HDDs/SSDs, please refer to:
section
"Right side 4 x 2.5-inch HDD backplane (A3C40196777)" on
page
153.
For configurations with up to eight 2.5-inch HDDs/SSDs, please refer to:
section
"Left side 4 x 2.5-inch HDD backplane (A3C40196780)" on
page 152
or
page
153.
RX1330 M3
Hard disk drive (HDD) / solid state drive (SSD)
"Right side 4 x 2.5-inch HDD backplane (A3C40196777)" on
Upgrade and Maintenance Manual
Hardware: 10 minutes
151