CAUTION!
Ensure to turn the screw clockwise in order to remove it!
Slowly and carefully increase the pressure on the screw until it begins
to turn. The effort when loosing the screw should be as low as
possible.
Otherwise the thin metal bar may break, rendering it impossible to
loosen the screw.
Ê Remove the TPM screw (3).
Ê Remove the TPM on the upper side of the system board.
Figure 204: Removing the TPM spacer
Ê Using a flat nose pliers, press together the hooks on the TPM spacer (1, see
close-up) and remove it from the system board (2).
I
If the TPM is to be replaced, the TPM spacer may remain on the
system board.