Fujitsu PRIMERGY RX1330 M3 Upgrade And Maintenance Manual page 306

Hide thumbs Also See for PRIMERGY RX1330 M3:
Table of Contents

Advertisement

System board and components
Figure 214: Removing the system board
Ê Use both hands to lift the system board carefully out of the chassis in a slight
angle. Thereby you pull the connectors out of the connector panel.
V
CAUTION!
Always take the system board with both hands!
Never lift the system board one-sided or at a heat sink, because the
solder connections between the socket and the system board come
under tension and increase the risk of damage and malfunction!
Don't damage the EMI springs which are essential to comply with
applicable EMC regulations and satisfy cooling requirements and fire
protection measures.
Ê Place the removed and the new system board on an antistatic surface.
Ê Remove the TPM as described in section
306
Upgrade and Maintenance Manual
"Removing the TPM" on page
288.
RX1330 M3