6.4

Basic operations

Overview
● Editable parameters: all P parameters under the "Para" menu are settable parameters.
Seven groups in total are available:
– P 0A: basic
– P 0B: gain adjustment
– P 0C: speed control
– P 0D: torque control
– P 0E: position control
– P 0F: I/O
– P All: all parameters
● Read-only parameters: All r parameters under the "Data" menu are read-only parameters.
You can only read values of these parameters.
Parameters with index
Some parameters have several indices. Each index has its own meaning and corresponding
value.
Parameters without index
All parameters that do not have indices are parameters without index.
6.4.1

Editing parameters

You can edit a parameter value in two methods:
● Method 1: change the value directly with the UP or DOWN button
● Method 2: move the cursor to a digit with the SHIFT button, then change the digit value
with the UP or DOWN button
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2016, A5E36037884-002
Basic operator panel (BOP)
6.4 Basic operations
147