Par. No.
Name
p31585
VIBSUP: Filter frequency
f
d
Description: Sets the frequency of the damped natural vibration of the mechanical system. This frequency can
be determined by making the appropriate measurements.
Note: The maximum frequency that can be set depends on the filter sampling time.
p31586
VIBSUP: Filter damping
Description: Sets the value for the damping of the natural mechanical vibration to be filtered. Typically, the
damping value is about 0.03, and can be optimized by performing the appropriate positioning tests.
Read-only parameters
Par. No.
Name
r0020
Speed setpoint smoothed
Description: Displays the currently smoothed speed setpoint at the input of the speed controller or U/f charac-
teristic (after the interpolator).
Note: Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
The speed setpoint is available smoothed (r0020) and unsmoothed.
r0021
Actual speed smoothed
Description: Displays the smoothed actual value of the motor speed.
Note: Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
The speed actual value is available smoothed (r0021) and unsmoothed.
r0026
DC link voltage smoothed
Description: Displays the smoothed actual value of the DC link voltage.
Note: Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
The DC link voltage is available smoothed.
r0027
Absolute actual current smoothed
Description: Displays the smoothed absolute actual current value.
Notice: This smoothed signal is not suitable for diagnostics or evaluation of dynamic operations. In this case,
the unsmoothed value should be used.
Note: Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
The absolute current actual value is available smoothed (r0027) and unsmoothed.
r0029
Current actual value field-generating smoothed
Description: Displays the smoothed field-generating actual current.
Note: Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
The field-generating current actual value is available smoothed (r0029) and unsmoothed.
r0030
Current actual value torque-generating smoothed
Description: Displays the smoothed torque-generating actual current.
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2016, A5E36037884-002
Min
Max
0.5
62.5
0.00
0.99
Factory
Unit
Data
Setting
type
1
Hz
Float 32
0.03
-
Float 32
Unit
rpm
rpm
V
Arms
Arms
Arms
Parameters
10.2 Parameter list
Effective
Can be
changed
IM
T
IM
T
Data type
Float
Float
Float
Float
Float
Float
317