Parameters
10.2 Parameter list
Par. No.
Name
p29300
Digital input forced sig-
nals
Description: assignment signals are forced to be high. 7 bits in total.
Bit 0: SON
Bit 1: CWL
Bit 2: CCWL
Bit 3: TLIM1
Bit 4: SPD1
Bit 5: TSET
Bit 6: EMGS
If one or more bits are set to be high, the corresponding input signals are forced to be logical high signals.
Note: The drive unit displays the value in hex format. To know the logic (high/low) assignment to each bit, you
must convert the hex number to the binary number, for example, FF (hex) = 11111111 (bin).
p29301[0..
Digital input 1 assignment 0
.3]
Description: Defines the function of digital input signal DI1 (PTI mode)
SON 1
RESET 2
CWL 3
CCWL 4
G-CHANGE 5
P-TRG 6
CLR 7
EGEAR1 8
EGEAR2 9
TLIMT1 10
TLIMT2 11
CWE 12
CCWE 13
ZSCLAMP 14
SPD1 15
SPD2 16
SPD3 17
TSET 18
SLIMT1 19
SLIMT2 20
POS1 21
POS2 22
POS3 23
REF 24
SREF 25
STEPF 26
STEPB 27
STEPH 28
312
Min
Max
0
127
28
Factory
Unit
Data
Setting
type
0
-
U32
1
-
I16
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2016, A5E36037884-002
Effective
Can be
changed
IM
T, U
IM
T