10 Stepping motor parameters and characteristics
10.1

Basic concepts

Step angle
Number of steps
Holding torque
Systematic angle
tolerance
Control and stepping
frequency
Speed
Torques
10-2
A number of certain parameters and characteristics must be known for
examining and selecting a stepping motor. Each stepping motor has its
specific properties in conjunction with the power controller used; these
properties are represented by characteristic curves. To facilitate an
understanding of their contents and meaning, the essential parameters
and the usage of the characteristics are explained here.
A step refers to a motor shaft rotation by the step angle ; the step is
initiated by a control pulse.
The number of steps specifies the number of steps the rotor performs per
revolution. The number of steps can be adjusted for a 3-phase stepping
motor.
The rotor is held in each step position due to the DC excitation of the coils
unless its holding torque M
The systematic angle tolerance per step ∆α
number of angular minutes a step may deviate from the nominal step
angle.
With a continuous sequence of control pulses at a control frequency f
the motor shaft will also execute a sequence of steps at the (same)
stepping frequency f
.
Z
From a specific control frequency onwards (depending on motor type and
mechanical load) the step-by-step movement of the motor shaft verges
into a continuous rotary movement. The following then applies fro the
speed n of the motor:
n = α/360° · f
Z
If the rotating motor shaft is subjected to a load torque M
continue to follow the control frequeny synchronously unless the load
torque exceeds a certain limit, i.e. the maximum torque at maximum slew
stepping rate M
.
Bm
In this case, the rotor cannot follow the control frequency any more, and a
step "loss" will occur, where control frequency and stepping frequency are
no longer identical.
Such a situation can be avoided by selecting the correct motor and by
controlling it correctly
is exceeded on the motor shaft.
H
specifies the maximum
s
· 60 r.p.m. (f
[Hz])
z