7.2

General functions

7.2.1

Travel to fixed stop

The function of travelling to fixed stop can be used, for example, to traverse sleeves to a
fixed stop against the workpiece with a predefined torque. In this way, the workpiece can be
securely clamped.
Function behavior in PTI control mode
You can configure the function of travelling to fixed stop by setting the following parameter:
Parameter
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2016, A5E36037884-002
Value
p29045
1
0
Description
Travel to fixed stop is active.
Travel to fixed stop is inactive.