Name
p0795
Digital inputs simulation
mode
Description: Sets the simulation mode for digital inputs.
Bit 0 to bit 9: set the simulation mode for DI 1 to DI 10
Bit = 0: terminal eval
Bit = 1: simulation
Note: If a digital input is used as signal source for the function "STO" then it is not permissible to select the
simulation mode and this is rejected.
This parameter is not saved when data is backed up.
p0796
Digital inputs simulation
mode setpoint
Description: Sets the setpoint for the input signals in the digital input simulation mode.
Bit 0 to bit 9: set the setpoint for DI 1 to DI 10
Bit = 0: low
Bit = 1: high
Note: This parameter is not saved when data is backed up.
p1001
Fixed speed setpoint 1
Description: Sets a value for the fixed speed / velocity setpoint 1.
p1002
Fixed speed setpoint 2
Description: Sets a value for the fixed speed / velocity setpoint 2.
p1003
Fixed speed setpoint 3
Description: Sets a value for the fixed speed / velocity setpoint 3.
p1004
Fixed speed setpoint 4
Description: Sets a value for the fixed speed / velocity setpoint 4.
p1005
Fixed speed setpoint 5
Description: Sets a value for the fixed speed / velocity setpoint 5.
p1006
Fixed speed setpoint 6
Description: Sets a value for the fixed speed / velocity setpoint 6.
p1007
Fixed speed setpoint 7
Description: Sets a value for the fixed speed / velocity setpoint 7.
p1058
Jog 1 speed setpoint
Description: Sets the speed/velocity for jog 1. Jogging is level-triggered and allows the motor to be incremen-
tally moved.
Note: The parameter values displayed on the BOP are integers.
p1082 *
Maximum speed
Description: Sets the highest possible speed.
Notice: After the value has been modified, no further parameter modifications can be made.
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2016, A5E36037884-002
Min
Max
1
429496729
5
1
429496729
5
-210000.000
210000.000 0.000
-210000.000
210000.000 0.000
-210000.000
210000.000 00.000
-210000.000
210000.000 0.000
-210000.000
210000.000 0.000
-210000.000
210000.000 0.000
-210000.000
210000.000 0.000
0.00
210000.000 100.00
0.000
210000.000 1500.00
Factory
Unit
Data
Setting
type
0
-
U32
0
-
U32
rpm
Float
rpm
Float
rpm
Float
rpm
Float
rpm
Float
rpm
Float
rpm
Float
rpm
Float
rpm
Float
0
Parameters
10.2 Parameter list
Effective
Can be
changed
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T
IM
T