Settings For Brand-New Converters; Basic Settings - Siemens SINAMICS SIMOTICS S200 PROFINET Operating Instructions Manual

Servo drive system
Table of Contents

Advertisement

7.3.2

Settings for brand-new converters

Overview
The basis settings are required before performing first commissioning for a brand-new
converter.
Requirement
• The operating unit is connected to the converter via the service interface X127 or the
PROFINET interface X150.
• The web server is accessed with the IP address:
– For service interface X127: 169.254.11.22 (default)
– For PROFINET interface X150: 0.0.0.0 (default)
Description of function
If the web server is called, a forwarding function starts automatically to define the following
settings:
• Basic settings (Page 173)
• Security settings (Page 174)
7.3.3

Basic settings

Overview
Initial basic settings are defined in the function view.
Requirement
The web server is being called for the first time.
Description of function
The basic settings are as follows:
• Preferred language of the user interface
• Converter date and time; either manually or via NTP
After these entries have been made, using the "Next" button, you can continue to the
Security Wizard.
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
Before you establish an online connection via PROFINET, you must configure a suitable IP
address for the PROFINET interface. With firmware V6.2, the configuration is possible in
Startdrive only.
Commissioning (web server)
7.3 Getting started
173