Siemens SINAMICS V90 Operating Instructions Manual page 100

Hide thumbs Also See for SINAMICS V90:
Table of Contents

Advertisement

Connecting
4.3 Control/status interface - X8
Parameterization
Two parameters, p29350 (selects signal sources for AO1) and p29351 (selects signal
sources for AO2), are used to select the source of analog output:
Parameter
Value
p29350
0 (default) Actual speed (reference p29060)
1
2
3
4
5
6
p29351
0
1 (default) Actual torque (reference 3 × r0333)
2
3
4
5
6
Wiring
Do wiring of analog outputs as follows:
100
Source
Actual torque (reference 3 × r0333)
Speed setpoint (reference p29060)
Torque setpoint (reference 3 × r0333)
DC bus voltage (reference 1000 V)
Pulse input frequency (reference 1 k)
Pulse input frequency (reference 10 k)
Actual speed (reference p29060)
Speed setpoint (reference p29060)
Torque setpoint (reference 3 × r0333)
DC bus voltage (reference 1000 V)
Pulse input frequency (reference 1 k)
Pulse input frequency (reference 10 k)
Value
7
Pulse input frequency (reference 100 k)
8
Pulse input frequency (reference 1000 k)
9
Remaining number of pulses (reference
1 k)
10
Remaining number of pulses (reference
10 k)
11
Remaining number of pulses (reference
100 k)
12
Remaining number of pulses (reference
1000 k)
7
Pulse input frequency (reference 100 k)
8
Pulse input frequency (reference 1000 k)
9
Remaining number of pulses (reference
1 k)
10
Remaining number of pulses (reference
10 k)
11
Remaining number of pulses (reference
100 k)
12
Remaining number of pulses (reference
1000 k)
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2016, A5E36037884-002