Siemens SINAMICS V90 Operating Instructions Manual page 323

Hide thumbs Also See for SINAMICS V90:
Table of Contents

Advertisement

Par. No.
Name
Index:
[0]: Firmware version
[1]: Build increment number
r29400
Internal control signal status indicating
Description: Control signal status identifiers
Bit 0 SON, Bit 1 RESET, Bit 2 CWL, Bit 3 CCWL, Bit 4 G-CHANGE, Bit 5 P-TRG, Bit 6 CLR, Bit 7 EGEAR1,
Bit 8 EGEAR2, Bit 9 TLIMT1, Bit 10 TLIMT2, Bit 11 CWE, Bit 12 CCWE, Bit 13 ZSCLAMP, Bit 14 SPD1, Bit
15 SPD2, Bit 16 SPD3, Bit 17 TSET, Bit 18 SLIMT1, Bit 19 SLIMT2, Bit 20 POS1, Bit 21 POS2, Bit 22 POS3,
Bit 23 REF, Bit 24 SREF, Bit 25 STEPF, Bit 26 STEPB, Bit 27 STEPH, Bit 28 EMGS, Bit 29 C-MODE
r29942
DO signals status indicating
Description: Indicates the status of DO signals.
Bit 0: RDY
Bit 1: FAULT
Bit 2: INP
Bit 3: ZSP
Bit 4: SPDR
Bit 5: TLR
Bit 6: SPLR
Bit 7: MBR
Bit 8: OLL
Bit 9: WARNING1
Bit 10: WARNING2
Bit 11: REFOK
Bit 12: CM_STA
Bit 13: RDY_ON
r29979
Index of actual electronic gear
Description: Displays the status of position loop.
Bit 0 to Bit 1: Actual EGear index
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2016, A5E36037884-002
Parameters
10.2 Parameter list
Unit
Data type
-
U32
-
U32
-
U32