Simatic S7-1200 - Siemens SINAMICS V90 Operating Instructions Manual

Hide thumbs Also See for SINAMICS V90:
Table of Contents

Advertisement

Connecting
4.3 Control/status interface - X8
4.3.5.3

SIMATIC S7-1200

Pulse train input position control (PTI)
*
**
114
The resistor R3 (200 Ohm to 500 Ohm) is required only if the speed for searching the
zero position exceeds 300 rpm.
The resistor R (200 Ohm to 500 Ohm, recommended power ≥ 5 W ) is required only if
the PTI input frequency exceeds 100 KHz.
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2016, A5E36037884-002

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotics s-1fl6

Table of Contents