Symmetricom TimeCreator 1000 User Manual page 214

Docsis timing interface server
Hide thumbs Also See for TimeCreator 1000:
Table of Contents

Advertisement

Appendix B Command Descriptions and Communications Interface
CLI Commands
To set the TOD mode to verbose -
tc1000>set interface tod-mode verbose
Example 4:
To provision Port A as a server port -
tc1000>set interface type porta server
Example 5:
To set the priority value for Port A to a value of 2 and the priority value of Port B to a
value of 3 -
tc1000>set interface priority porta 2
tc1000>set interface priority portb 3
Remarks: Rear panel ports A/11 and B/12 are referred to as ports A and B for the
interface state and type commands.
If the priority of the ports are the same, the port selection is non-revertive. For
instance:
1. If one port is disqualified and the second port is qualified, the second port will be
used as the reference.
2. If the first port is once again qualified, then the unit will not switch back to using
the first port; it will continue to use the second port as reference.
Set the ToD source to the desired value before setting the interface state or type.
The type should be set before the state is set for ports 11 and 12. Ports A/11 and
B/12 must be configured as server ports for the test signal is generated in test
mode. If test mode is enabled, the test signal is generated regardless of the port
enable/disable state setting.
Level :
Power-User and Admin only
214 TimeCreator 1000 User's Guide
097-93100-01 Revision C – February, 2010

Hide quick links: