Table A-9. TimeCreator Events Traps - Additional Details (Continued)
OID
Trap OID Name
Index
(y)
43
trapIOCRemoved
(id = 308)
44
trapPowerRemoved
(id = 309)
45
trapUTCAvailable
(id = 317)
46
trapMTIETAlarm
(id = 321)
47
trapMTIE35Alarm
(id = 322)
097-93100-01 Revision C – February, 2010
Description
IOC <#> has been
trapID:
removed
trapAID1: 1 or 2,
IOC <#> has been
inserted
trapAID2: n/a
trapState: clear (1),
trapValue: n/a
Power Module <#>
trapID:
has been removed
trapAID1: 1 or 2,
Power Module <#>
has been inserted
trapAID2: n/a
trapState: clear (1),
trapValue: n/a
UTC time from GPS
trapID:
is available
trapAID1: n/a
trapAID2: n/a
trapState:
trapValue: n/a
Port <#> MTIE-t
trapID:
threshold set to 0,
trapAID1: port #
alarm disabled
trapAID2: n/a
Port <#> MTIE-t
trapState: clear (1),
threshold set above
0, alarm enabled
trapValue: n/a
Port <#> MTIE-35
trapID:
threshold set to 0,
trapAID1: port #
alarm disabled
trapAID2: n/a
Port <#> MTIE-35
trapState: clear (1),
threshold set above
0, alarm enabled
trapValue: n/a
Appendix A Alarms, Events and SNMP Traps
Bindings
IOCREMOVED
IOC module id
set (2)
PWRREMOVED
power module #
set (2)
UTCAVA
set (2)
MTIETALA
set (2)
MTIE35ALA
set (2)
TimeCreator 1000 User's Guide 171
SNMP Traps
Severity
nonalarm
nonalarm
nonalarm
nonalarm
nonalarm

Hide quick links: