Table A-2. System Notification Messages - Alarms (Continued)
Trap Name
Index
(trapID)
12
IMCFAIL
13
IMCNCOMP
14
GPSNCOM
15
MTIETEXC
097-93100-01 Revision C – February, 2010
Severity
Trap Messages
(default)
(trapDescription)
Critical
IMC operational
failure
IMC recovered
from operational
failure
Minor
IMC and IOC <#>
incompatible
IMC and IOC <#>
compatible
Minor
GPS antenna
communication
failed
GPS antenna
communication
restored
Minor
Port <#> has
exceeded the
MTIE-t threshold,
<value>
Port <#> is within
the MTIE-t
threshold,
<value>
Appendix A Alarms, Events and SNMP Traps
Description
Indicates that
Re-seat the IMC
the specified
module, if issue
IMC module is
not is resolved,
not functioning
replace module
properly
Indicates that
No action required
the specified
IMC module is
now functioning
properly
Indicates that
Need to upgrade
the IMC and IOC
IOCs or IMC to
modules are not
same firmware
compatible
versions
IMC and IOC
No action required
modules are
compatible
Indicates that
Check antenna
the GPS signal
cable, lightning
is not connected
arrestor and
antenna; replace
faulty item
Indicates that
No action required
the GPS signal
is OK
Indicates that
Check cable and
the MTIE-t error
NE (network
rate has
element) on that
exceeded the
port
user-set
threshold
Indicates that
No action required
the MTIE-t error
rate is within the
user-set
threshold