Table A-2. System Notification Messages - Alarms (Continued)
Trap Name
Index
(trapID)
20
PWRFANFAIL
21
NOIOC
22
JAMSYNC
23
DCMUNLOCK
24
PLLUNLOCK
097-93100-01 Revision C – February, 2010
Severity
Trap Messages
(default)
(trapDescription)
Major
Power Module
<#> fan failure
Power Module
<#> fan failure
cleared
Minor
No IOC module
in system
One or more IOC
modules in
system
Minor
Jam sync
required
Jam sync
completed
Major
IOC <#> DCM
unlocked
IOC <#> DCM
locked
Major
IOC <#> PLL
unlocked
IOC <#> PLL
locked
Appendix A Alarms, Events and SNMP Traps
Description
The fan of power
Check fan and if
module A or B
not spinning or
failed
alarm persists
then replace
power module
The fan of power
No action required
module A or B is
ok
Both IOC
Insert IOC module
modules are
removed
At least one IOC
No action required
module in the
system
Need to jam
Run the "sync
sync the IOC
TOD-source now"
module
command
Jam sync of IOC
No action required
module is
completed
Distributed clock
Hardware failure,
module has
contact
become
Symmetricom tech
unlocked
support
Distributed clock
No action required
module has
become locked
Phase clock
Hardware failure,
module has
contact
become
Symmetricom tech
unlocked
support
Phase clock
No action required
module has
become locked