Symmetricom TimeCreator 1000 User Manual page 180

Docsis timing interface server
Hide thumbs Also See for TimeCreator 1000:
Table of Contents

Advertisement

Appendix B Command Descriptions and Communications Interface
CLI Commands
Set Alarm-State
This command is used to enable or disable specific alarms.
of alarm codes and their description.
Command Syntax:
set alarm-state <alarm code> {enable|disable}
Example:
To enable the alarm for IOC in holdover for extended period (alarm code of EXTHOLD) -
tc1000>set alarm-state exthold enable
Related:
show alarm-state
Level:
Power-User and Admin only
Table B-1. TimeCreator 1000 Alarm Codes
Alarm Code
IOCFAIL
IMCFAIL
IMCCOM
IOCCOM
OUTDISC
INPDISC
ADV
INPCBL
INPUNSTBL
INPDISQ
IOCINCOMP
IMCINCOMP
EXTHOLD
GPSCOMM
MTIET
MTIE35
180 TimeCreator 1000 User's Guide
Description
IOC card failure
IMC card failure
IMC communication failure
IOC communication failure
DTI output disconnect
DTI input disconnect
DTI input cable advance invalid
DTI input performance unstable
DTI Input disqualified
IOC cardss are incompatible
IMC and IOC are incompatible
IOC in holdover for extended period
GPS communications failure
MTIE-t threshold exceeded
MTIE-35 threshold exceeded
Table A-2
provides a list
097-93100-01 Revision C – February, 2010

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents