2.10.2 Area Text; Cc# Arm Now Warn; Cc# Close Door; Cc# Enhanccmdctr - Bosch D9412G Program Entry Manual

Table of Contents

Advertisement

D9412G/D7412G | Program Entry Guide | 2.0 9000MAIN
0101
This prompt allows you to manage the
0101
tone by command center. Exit Tone can
0101
also be turned off when programming A#
Exit Tone in Area Parameters.
Assign two CCs to the same area so one
command center emits the tone and
another does not.

CC# Arm Now Warn

Default:
No
Selection:
Yes or No
Yes
This command center activates a tone
and displays PLEASE CLOSE NOW.
No
This command center does not activate
the tone or display PLEASE CLOSE
NOW.
Determines whether this command center sounds an
audible tone and displays the PLEASE CLOSE NOW
warning on the command center when a Closing
Window activates, indicating the area automatically
arms soon.

CC# Close Door

Default:
No
Selection:
Yes or No
Yes
This command center sounds a tone
and displays CLOSE DOOR #.
No
This command center does not sound
the tone or activate the display.
Determines whether this command center sounds an
audible tone and displays the CLOSE DOOR #
warning on the command center. This occurs when
the door is physically held open past the shunt time
and the extend time has a value greater than zero
(see the Access Program Entry Guide) for the door
assigned to this area in

CC# EnhancCmdCtr

Default:
No
Selection:
Yes or No
Yes
This command center is a D1260
Alpha V Command Center.
No
This command center is not a D1260
Alpha V Command Center.
Bosch Security Systems | 10/03 | 47775E
CC# Assign Door
.
When a D1260 Alpha V Command Center is
installed at this command center address, this item
must be set to Yes. This instructs the control panel to
send additional information to the D1260 required
for proper operation.
0101
Remember to program CC# Supervised
0101
to Yes if a D1260 Alpha V Command
0101
Center is installed at this address. Failure
to follow this programming requirement
results in improper operation of the
D1260.

2.10.2 Area Text

Use this programming category to create custom
Idle Text displays for the command centers.
Each display can be programmed with up
to sixteen alphanumeric characters,
including: A to Z, 0 to 9, ?, &, @, -, *,
+, $, #, _, /.
Characters not listed are invalid and
cannot be used for text.

Area

Default:
1
Selection:
1 to 8
Enter the area number you are programming.

Area# Is On

Program Record Sheet
Default:
See
Selection:
Enter the text for this area that displays when the
area is master armed or master instant armed and
other areas sharing the same account number are not
yet master armed. This display does not appear
when the area is perimeter armed.

Area # Not Ready

Program Record Sheet
Default:
See
Selection:
Sixteen alphanumeric characters
Enter the text for this area that displays when the
area is disarmed but points are faulted.

Area # Is Off

Program Record Sheet
Default:
See
Selection:
Sixteen alphanumeric characters
Enter the text for this area that displays when the
area is disarmed and no points are faulted.
EN | 50

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D7412g

Table of Contents