Siemens siprotec SJ62 User Manual page 708

Multi-functional protective relay with local control
Table of Contents

Advertisement

Project
Protection devices
Reorganizing
RIO file
RSxxx-interface
SCADA Interface
Service port
Setting parameters
SI
SI_F
SICAM SAS
SICAM SC
SICAM WinCC
Single command
Single point indica-
tion
SIPROTEC
SIPROTEC 4, 7SJ62/63/64 Handbuch
C53000-G1140-C147-A, Edition 07.2015
Content-wise, a project is the image of a real power supply system. Graphically, a
project is represented by a number of objects which are integrated in a hierarchical
structure. Physically, a project consists of a series of folders and files containing
project data.
All devices with a protective function and no control display.
Frequent addition and deletion of objects creates memory areas that can no longer be
used. By cleaning up projects, you can release these memory areas. However, a clean
up also reassigns the VD addresses. As a consequence, all SIPROTEC 4 devices
need to be reinitialized.
Relay data Interchange format by Omicron.
Serial interfaces RS232, RS422/485
Rear serial interface on the devices for connecting to a control system via IEC or
PROFIBUS.
Rear serial interface on the devices for connecting DIGSI (for example, via modem).
General term for all adjustments made to the device. Parameterization jobs are exe-
cuted by means of DIGSI or, in some cases, directly on the device.
→ Single point indication
→ Single-point indication fleeting → Transient information, → Single-point indication
Modular substation automation system based on the substation controller → SICAM
SC and the SICAM WinCC operator control and monitoring system.
Substation Controller. Modularly substation control system, based on the SIMATIC M7
automation system.
The SICAM WinCC operator control and monitoring system displays the condition of
your network graphically, visualizes alarms and indications, archives the network data,
allows to intervene manually in the process and manages the system rights of the in-
dividual employee.
Single commands are process outputs which indicate 2 process states (for example,
ON/OFF) at one output.
Single indications are items of process information which indicate 2 process states (for
example, ON/OFF) at one output.
The registered trademark SIPROTEC is used for devices implemented on system
base V4.
Glossary