4 Technical Data
System Interface
451
IEC 60870-5-103
RS232
RS485
Fiber Optical Link (FO)
PROFIBUS RS485
(FMS and DP)
RS232/RS485/FO accord-
ing to the ordering variant
Connection for flush-
mounted case
Connection for surface
mounting housing
Test Voltage
Transmission Speed
Maximum Distance of
Transmission
Connection for flush-
mounted case
Connection for surface
mounting housing
Test Voltage
Transmission Speed
Maximum Distance of
Transmission
FO connector type
Connection for flush-
mounted case
Connection for surface
mounting housing
Optical Wavelength
Laser Class 1 according to
EN 60825-1/-2
Permissible Optical Link
Signal Attenuation
Maximum Distance of
Transmission
Character Idle State
Connection for flush-
mounted case
Connection for surface
mounting housing
Test Voltage
Transmission Speed
Maximum Distance of
Transmission
isolated interface for data transfer to a
master terminal
Rear panel, mounting location „B", 9-
pin D-SUB miniature connector
at the housing mounted case on the
case bottom
500 VAC
min. 4,800 Baud; max. 38,400 Baud;
Factory setting 9600 Baud
49.2 feet (15 m)
Rear panel, mounting location „B", 9-
pin D-SUB miniature connector
at the housing mounted case on the
case bottom
500 VAC
min. 4,800 Baud; max. 38,400 Baud;
Factory setting 9600 Baud
max. 0.62 miles (1 km)
ST connector
Rear panel, mounting location „B"
at the housing mounted case on the
case bottom
λ = 820 nm
using glass fiber 50/12 μm or using
glass fiber 62.5/125 μm
max. 8 dB, with glass fiber 62.5/125
μm
max. 0.93 miles (1.5 km)
Configurable: factory setting „Light off"
Rear panel, mounting location „B" 9-
pin D-SUB miniature connector
at the housing mounted case on the
case bottom
500 VAC
up to 1.5 MBd
3,280 ft or 1,000 m at ≤ 93.75 kBd
500 m or 1,640 ft at ≤ 187.5 kBd
200 m or 330 ft at ≤ 1.5 MBd
SIPROTEC 4, 7SJ62/63/64 Handbuch