Siemens siprotec SJ62 User Manual page 687

Multi-functional protective relay with local control
Table of Contents

Advertisement

A Appendix
No.
Description
2890
79 2nd cycle zone extension
release (79 2.CycZoneRel)
2891
79 3rd cycle zone extension
release (79 3.CycZoneRel)
2892
79 4th cycle zone extension
release (79 4.CycZoneRel)
2896
No. of 1st AR-cycle CLOSE com-
mands,3pole (79 #Close1./3p=)
2898
No. of higher AR-cycle CLOSE
commands,3p (79 #Close2./3p=)
2899
79: Close request to Control
Function (79 CloseRequest)
4601
>52-a contact (OPEN, if bkr is
open) (>52-a)
4602
>52-b contact (OPEN, if bkr is
closed) (>52-b)
4822
>BLOCK Motor Startup counter
(>BLOCK 66)
4823
>Emergency start (>66 em-
er.start)
4824
66 Motor start protection OFF (66
OFF)
4825
66 Motor start protection
BLOCKED (66 BLOCKED)
4826
66 Motor start protection ACTIVE
(66 ACTIVE)
4827
66 Motor start protection TRIP
(66 TRIP)
4828
>66 Reset thermal memory (>66
RM th.repl.)
4829
66 Reset thermal memory (66
RM th.repl.)
5143
>BLOCK 46 (>BLOCK 46)
5145
>Reverse Phase Rotation (>Re-
verse Rot.)
5147
Phase rotation ABC (Rotation
ABC)
5148
Phase rotation ACB (Rotation
ACB)
5151
46 switched OFF (46 OFF)
5152
46 is BLOCKED (46 BLOCKED) 46 Negative Seq
5153
46 is ACTIVE (46 ACTIVE)
5159
46-2 picked up (46-2 picked up)
5165
46-1 picked up (46-1 picked up)
5166
46-TOC picked up (46-TOC
pickedup)
5170
46 TRIP (46 TRIP)
5171
46 Disk emulation picked up (46
Dsk pickedup)
5203
>BLOCK 81O/U (>BLOCK
81O/U)
685
Function
Type
of In-
for-
matio
n
79M Auto Recl.
OUT
*
79M Auto Recl.
OUT
*
79M Auto Recl.
OUT
*
Statistics
VI
Statistics
VI
79M Auto Recl.
OUT
*
P.System Data 2
SP
On
Off
P.System Data 2
SP
On
Off
48/66 Motor
SP
*
48/66 Motor
SP
On
Off
48/66 Motor
OUT
On
Off
48/66 Motor
OUT
On
Off
48/66 Motor
OUT
On
Off
48/66 Motor
OUT
On
Off
48/66 Motor
SP
On
Off
48/66 Motor
OUT
On
Off
46 Negative Seq
SP
*
P.System Data 1
SP
On
Off
P.System Data 1
OUT
On
Off
P.System Data 1
OUT
On
Off
46 Negative Seq
OUT
On
Off
OUT
On
Off
46 Negative Seq
OUT
On
Off
46 Negative Seq
OUT
*
46 Negative Seq
OUT
*
46 Negative Seq
OUT
*
46 Negative Seq
OUT
*
46 Negative Seq
OUT
*
81 O/U Freq.
SP
On
Off
Log Buffers
Configurable in Matrix
*
*
LED
*
*
LED
*
*
LED
on
*
LED
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED
On
*
LED
Off
*
*
LED
*
*
LED
*
*
LED BI
*
*
LED
*
*
LED BI
*
*
LED BI
*
*
LED
*
*
LED
*
*
LED
On
*
LED
Off
*
*
LED
On
*
LED
Off
On
*
LED
Off
On
*
LED
Off
on
m
LED
*
*
LED
*
*
LED BI
SIPROTEC 4, 7SJ62/63/64 Handbuch
C53000-G1140-C147-A, Edition 07.2015
IEC 60870-5-103
BO
BO
BO
BO
BO
BO
BO
BO
168
51
1
Yes
BO
168
52
1
Yes
BO
168
53
1
Yes
BO
168
54
1
Yes
BO
168
55
1
Yes
BO
BO
BO
70
126
1
Yes
BO
BO
70
128
1
Yes
BO
70
129
1
Yes
BO
70
131
1
Yes
BO
70
132
1
Yes
BO
70
133
1
Yes
BO
70
138
2
Yes
BO
70
150
2
Yes
BO
70
141
2
Yes
BO
70
149
2
Yes
BO
BO
70
176
1
Yes

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Siprotec sj63Siprotec sj64