Citizen CL-E700 series Technical Manual page 140

Thermal transfer printer
Hide thumbs Also See for CL-E700 series:
Table of Contents

Advertisement

Chapter 3 Disassembly and Maintenance
3-7. Adjustments
Procedure:
*
For detailed menu operation in Factory mode, refer to
mode" in Chapter 2.
1. Enter Factory/Service mode by turning on the power while pressing and holding the
[MENU], [FEED] (
"Factory Setup" main menu appears.
Main Menu
Factory Setup
2. In "Factory Setup" main menu, press the [STOP] (
mode.
The first submenu "Init Thru Sen" is displayed.
3. Press the [MENU] key until "Init Refl Sen" submenu appears.
Factory Setup
Init Refl Sen
4. Press the [STOP] (
Init Refl Sen
5. Press the [MENU] key to select "Exec".
Init Refl Sen
6. Press the [STOP] (
Adjustment starts and the following screen is display.
Now !!
Executing
7. Be sure that adjustment is successfully completed and the following screen is
displayed. (The value "123" is an example.)
Finished
DAC 123
CL-E700 series
) and [STOP] (
) key to enter "IInit Refl Sen" sensitivity adjustment mode.
No
Exec
) key to execute adjustment.
"2-3-3. Factory/Service
) keys.
) key to enter Factory Setup
3-54