3-6-6. "SA Ribbon Motor F" and "SA Ribbon Control PCB"
1. Remove the "SA2 Ribbon Unit Fan". Refer to
2. Disconnect the connectors J602 and J603 from the "SA Ribbon Control PCB".
3. Remove the 2 screws (BH M3.0x4 (NI)) and detach the "SA Ribbon Motor F".
4. Disconnect the connectors J606 and J601 (SA Ribbon Cable) from the "SA Ribbon Control
PCB".
5. Remove the 2 screws (BH M3.0x4 (NI)) and detach the "SA Ribbon Control PCB".
BH M3.0x4 (NI)
SA Ribbon Motor F
3-6-7. "Catch Ribbon Holder" and "Knob Ribbon Unit"
1. Remove the 4 screws (BH M3.0x3 (NI)) and detach the "Catch Ribbon Holder" (2 pcs.).
2. Remove the 2 screws (PHT(#2) M3.0x8 (NI)) and detach the "Knob Ribbon Unit".
BH M3.0x4 (NI)
SA Ribbon Control PCB
J603
J602
J606
Knob Ribbon Unit
Chapter 3 Disassembly and Maintenance
3-6. Disassembly, Reassembly and Lubrication
"3-6-3 "Unit Ribbon"
J601
SA Ribbon Cable
PHT(#2) M3.0x8 (NI)
BH M3.0x3 (NI)
3-
19
Covers".
[SA Ribbon Control PCB]
J604
J605
J603
J606
J602
J601
J304
BH M3.0x3 (NI)
Catch Ribbon Holder
CL-E700 series