Chapter 3 Disassembly and Maintenance
3-6. Disassembly, Reassembly and Lubrication
1. Remove the 1 screw (BH M3.0x5K) () and detach the "Cover PF Motor" () to the left.
2. Open the Head Block.
3. Remove the 1 screw (NO2 BH M3.0x12D) () and detach the "Cover PF Motor 2" ()
upwardly.
4. Disconnect the connector J304 () from the "SA Relay PCB".
5. Close the Head Block.
6. Remove the 2 screws (BH M3.0x4 (NI)) () and detach the "Unit Ribbon" () by lifting it
upwardly.
DO NOT loosen the following
correct ribbon running cannot be assured.
3
NO2 BH M3.0x12D
4
Cover PF Motor 2
1
BH M3.0x5K
2
Cover PF Motor
Note on reassembling:
• Mount the "Cover PF Motor 2" () with the Head Block opened.
CL-E700 series
"Forbidden
(SA Relay PCB)
Head Block
Screws". Once they are loosened,
BH M3.0x4 (NI)
6
DO NOT LOOSEN.
Forbidden Screws
5 J304
7
Unit Ribbon
3-14