Chapter 3 Disassembly and Maintenance
3-6. Disassembly, Reassembly and Lubrication
• Securely seat the "Cap Sensor Cable U" () in place as shown below. At this time,
engage its notched corner with the chassis.
10
FFC TRA Sensor
• When mounting the "Holder Sensor U" Block on the "Cover Head Wire" (), engage the
spring "Spring Sensor Frame" () as follows.
1) Insert the long end of the spring into the shorter slit in the "Cover Head Wire" ().
2) Hook a cable wire or similar on the short end of the spring, and pull it to lower the
short end of the spring.
3) While pulling the cable wire, mount the "Holder Sensor U" Block on the "Cover Head
Wire" (), and then hook the short end of the spring on the part "C" of the "Holder
Sensor U" Block.
2
Cover Head Wire
3
Spring Sensor Frame
CL-E700 series
15
Tape Sensor Cable U
Cap Sensor Cable U
6
Fixing the "Spring Sensor Frame"
(Shorter slit)
C
3-36
Cable wire for pulling
"Holder Sensor U" Block