Citizen CL-E700 series Technical Manual page 138

Thermal transfer printer
Hide thumbs Also See for CL-E700 series:
Table of Contents

Advertisement

Chapter 3 Disassembly and Maintenance
3-7. Adjustments
5. Press the [MENU] key to select "Exec".
Init Thru Sen
6. Press the [STOP] (
Adjustment starts and the following screen is display.
Now !!
Executing
7. Be sure that the adjustment is successfully completed and the following screen is
displayed. (The value "123" is an example.)
Finished
DAC 123
When the adjustment has failed:
"Cannot Setup" is displayed. In this case, follow the next
steps.
1) Press any key of the printer.
The screen returns to Step 3.
2) Check for correct media setting position, media, active
sensor, etc. and repeat from Step 3.
8. Press any key of the printer.
Then, the obtained value is saved into the printer and the screen returns to Step 3.
9. When the "SA Main PCB" or "SA Ref Sensor PCB" is replace, go to the following
item
"3-7-1(2-2) Init Refl Sen sensitivity
When the "SA TRA Sen PCB" is replaced proceed to the next step.
10. Press the [PAUSE] ( ) key to return to "Factory Setup" menu.
11. Press the [PAUSE] ( ) key once again.
The changed value is saved in the printer and the printer is restarted internally.
Then, the printer returns to normal operation.
CL-E700 series
Exec
) key to execute adjustment.
adjustment" to carry out further adjustment.
3-52
Cannot
Setup