Chapter 3 Disassembly and Maintenance
3-6. Disassembly, Reassembly and Lubrication
Notes on reassembling:
• Apply FLOIL G-311S along the tooth side of the slit as shown below.
• Tie the "SA Ref Sensor Cable" () with the 2 wire ties "Wire Tie" () as shown below.
• When mounting the "Plate Adj Sen L Spring" and "Spring Adjust Sensor L", direct them as
shown below.
5 Holder Adjust Sensor L
Plate Adj Sen L Spring
• When mounting the shaft "Shaft Sensor Guide" () (with the "Guide Paper Set" () and
"Holder Adjust Sensor L" (), align both ends of the shaft in place.
At this time, press down the "Holder Adjust Sensor L" () by pushing its top to insert the
"Spring Adjust Sensor L" into the slit. (Since the width of the "Spring Adjust Sensor L" is wider
than that of the slit, it is required to push in.
Push straight down the "Holder Adjust Sensor L" ().If it is pushed slantwise,
the "Spring Adjust Sensor L" can be damaged.
5
Spring Adjust Sensor L
• When the "SA Ref Sensor PCB" is replaced with a new one, be sure to perform the sensor
adjustment. Refer to
CL-E700 series
7
SA Ref Sensor Cable
J8
FLOIL G-311S
Press straight down.
Holder Adjust Sensor L
"3-7-1 Transparent/Reflective Sensor
6 Wire Tie
6 Wire Tie
NoO PH(4-0.3) M2x3 (NI)
Spring Adjust Sensor L
Caution
Slit
Adjustment".