Power Switch For Ce Marking And General Export (High Voltage); Power Switch For Ce Marking - JUKI MOL-254 Engineer's Manual

2-needle, automatic belt-loop attaching machine
Hide thumbs Also See for MOL-254:
Table of Contents

Advertisement

[3] Power switch for CE marking and general export (high voltage)

3-phase : for 380V, 400V
Black Sky blue
Black Green/yellow

[4] Power switch for CE marking

Single phase : for 220V, 230V, 240V
Black Sky blue
Black
Green/yellow
HA00303000A
Thermal setting : 2.5
Short cord for single phase
supplied with switch
HA00303000A
Thermal setting : 4.0
Short cord for single phase
supplied with switch
Black (sky blue)
Brown
Green/yellow
Black (sky blue)
Brown
Green/yellow
186
Control box side
M90285800A0
Power plug side
Control box side
M90285800A0
Perform cutting of the brown
wire on the plug side and attach
wire marker "N" on either one
of the black wires.
Power plug side