8
7
10
1. Install loop pull-out device base asm.
underside of the machine table.
2. Loosen screw
separate the solenoid valve in the direction of the
arrow mark and assemble the solenoid valve for
loop pull-out device.
(Assemble the solenoid valve in 7th or 8th position.)
At this time, securely insert the rubber ring supplied
as accessory to the solenoid valve. Otherwise, air
leakage will result.
3. Perform piping of solenoid valve port A to the speed
controller on the cylinder rod side and of solenoid
valve port B to the speed controller on the cylinder
end side respectively.
4. Connect the connector "VL10" from the solenoid
valve cable asm. to the solenoid valve for loop pull-
out device.
5. Insert the connector of the loop lock detector switch
1
into CN10 on the MAIN circuit board of the control
box.
6. Turn ON the upper DIP SW No. 4 located on the
right side of the operation box panel.
150
in the device solenoid valve unit,
on the