JUKI MOL-254 Engineer's Manual page 87

2-needle, automatic belt-loop attaching machine
Hide thumbs Also See for MOL-254:
Table of Contents

Advertisement

Adjustment Procedures
1. Loosen fixing screw
adjustment screw
of the loop cut center in the direction
A or B to adjust the position of the loop cut center.
2. Turn ON the power and supply air to the machine.
3. When the cut position has been adjusted, pull the belt
loop splice detector lever
amount of the loop.
4. Pressing the standard screen key, press ten key 3. Then,
the cross cut knife works. Actually cut the belt and make
sure of the cross cut position.
(Caution) The aforementioned operations can be
actuated only when the setting screen is
displayed.
in the knife base bracket and move
to this side to feed a small
80
Results of Improper Adjustment
○ If the cross cut center is not in
the regular position, dog ear will
result.